ISO 14971: Risk Management for Medical Devices

← Back to Insights

Introduction

ISO 14971 is the international standard for the application of risk management to medical devices. It provides a framework for manufacturers to identify hazards, estimate and evaluate risks, control risks, and monitor the effectiveness of controls throughout the product lifecycle.

What is ISO 14971?

ISO 14971:2019 "Application of risk management to medical devices" is the international standard that specifies a process for manufacturers to identify hazards associated with medical devices, estimate and evaluate the associated risks, control these risks, and monitor the effectiveness of controls throughout the device lifecycle.

Key Principles of ISO 14971

Risk Management Process

The standard defines a systematic approach to risk management consisting of:

Risk Management File

Manufacturers must establish and maintain a risk management file containing:

MDR Requirement

Under EU MDR 2017/745, risk management according to ISO 14971 is mandatory. The risk management file must be part of the technical documentation submitted for conformity assessment.

Risk Analysis Process

1. Hazard Identification

Systematic identification of known and foreseeable hazards including:

2. Risk Estimation

For each identified hazard, estimate:

3. Risk Evaluation

Compare estimated risks against pre-defined acceptability criteria to determine which risks require control measures.

Risk Control Measures

ISO 14971 specifies a hierarchy of risk control measures:

Priority 1: Inherent Safety by Design

Eliminate or reduce risks through design features (most effective approach).

Priority 2: Protective Measures

Implement protective measures in the device or manufacturing process (e.g., alarms, automatic shut-offs).

Priority 3: Information for Safety

Provide information to users through labeling, instructions for use, and training (least effective, used when other measures are not feasible).

Benefit-Risk Analysis

For residual risks that cannot be reduced further, manufacturers must demonstrate that the medical benefits outweigh the residual risks. This analysis should consider:

Post-Production Information

Risk management continues throughout the device lifecycle. Manufacturers must:

Integration with Quality Management

Risk management should be integrated with the quality management system (ISO 13485). Risk management activities should be documented and subject to the same controls as other quality processes.

Common Challenges

Challenge: Comprehensive Hazard Identification

Solution: Use multiple methods including FMEA, fault tree analysis, hazard checklists, and multidisciplinary team reviews.

Challenge: Demonstrating ALARP

Solution: Document all considered risk control options and justify why selected measures reduce risk "As Low As Reasonably Practicable."

Challenge: Maintaining Risk Management File

Solution: Establish clear procedures for updating the risk management file based on post-market data and design changes.

How We Can Help

At Noetus Solutions, we provide comprehensive risk management support for medical devices:

Need Risk Management Support?

Our team has extensive experience in implementing ISO 14971 risk management for medical devices across all risk classes. Contact us to discuss your risk management needs.

Need Risk Management Support?

Let's discuss how we can help you implement ISO 14971 for your medical devices.

Contact Us More Insights